+44 7700015041

Welcome to OxyPap!

Call us: +4477 000 15041
Write us: info@oxypap.com

Auto CPAP device ResMed S9 AutoSet

Be the first to review this product

S9 AutoSet
€1,165.00
resmed

We ship the product in 1 business day.

Call for more information.

Money back guarantee.

Product Description

Details

The AutoSet series of Automatic Positive Airway Pressure (APAP) machines have long been designed to maximize comfort while providing minimal therapy pressures at the optimal moment. ResMed builds upon the AutoSet Advantage algorithm and incorporates EPR with Easy-Breathe technology in a new post modern shell. The S9 Series aesthetics are a complete redesign with new features:

 

Key Product Features

 Intuitive Design
 Mask-Fit System
 Optional Climate Control Heated Humidifier
 SlimLine or (Optional) ClimateLine Tubing
 AutoSet with Easy-Breathe Technology
 Forced Oscillation Technique (FOT)
 Expiratory Pressure Relief (EPR)
 24dBA Sound Level
 Smart Start / Smart Stop
 On-Display Advanced Data Reporting
 Optional SkinIt Cover


Mask-Fit System

ResMed has incorporated a simple and effective tool for help with proper mask fitting. The Mask-Fit system allows users to preset a mask type, tailoring the S9 CPAP therapy to a particular mask style:

 Nasal

 Pillows

 Full Face

 

Once set, the Mask-Fit system runs a 3 minute seal integrity test, prior to therapy treatment. After 3 minutes, a Mask-Fit icon appears (a green or red smiley face). If the smiley face is red, adjustments are necessary until the smiley face turns green, then therapy will begin.

 

Optional Humidaire H5i Heated Humidifier with Climate Control

ResMed has re-invented the Humidaire line of CPAP humidifiers. The Humidaire H5i incorporates an intelligent humidity controlling technology. The Climate Control system is managed through a combination of S9 machines, H5i humidifier and ClimateLine heated tubing. There are five sensors throughout the system that monitor ambient temperature and patient airflow. The ClimateLine heated tubing uses a built-in mask temperature sensor to reach relative humidity at the mask. Sensors inside and outside the CPAP machine closely monitor changes in humidity and prevents condensation from forming inside the tube. Rainout can hinder CPAP therapy and affect compliance. With the H5i humidifier, set the level of humidity and attach the ClimateLine tubing to achieve a new level of comfort.

 

SlimLine and (Optional) ClimateLine Tubing

The S9 Series CPAP machines come standard with the new ResMed SlimLine Tubing. The small diameter air tube is ultra-light, flexible and provides a unique alternative to bulky, generic 6 foot hoses. ResMed also offers a Standard Hose.

The ClimateLine Tubing has an internal heated coil and mask temperature sensor that helps manage rainout throughout the hose. Climate Control algorithms measure temperatures from the humidifier to prevent condensation from forming. The ClimateLine Tubing can use the SlimLine Tubing Wrap to achieve total control of rainout.

 

Enhanced AutoSet Advantage

ResMed's AutoSet Advantage is the answer to providing 'just what you need, when you need it'. Pressure needs vary throughout the night. These variations depend on how deep the user is sleeping, body position, and other daily factors that can affect therapy levels. AutoSet Advantage effectively minimizes therapy and helps lower pressure-related side effects, like mouth-breathing and nasal dryness. The AutoSet Advantage has always provided a strong defense against a main types of sleeping events:

 Flow Limitations

 Snoring

 Obstructive Apneas

 

The Enhanced AutoSet Advantage now detects and responds to open events using an event responsive Forced Oscillation Technique (FOT). A different event response is generated when an open airway event is encountered.

 

AutoSet Algorithm

The AutoSet algorithm measures flow limitations such as snoring and apneas on a breath-by-breath basis. Therapy begins at a minimal pressure. When the user's airflow shows signs of flow limitation, the AutoSet algorithm gently increases pressure based on the intensity and duration of the event. Once the event clears, pressures gradually decrease over a 20 minute time frame. Flow limitation occurs as the upper airway begins to collapse, before snoring and apneas are detected. By gradually increasing therapy pressure, the AutoSet algorithm reacts preemptively, resulting in lower average treatment pressures.

For example, as you sleep on your side, pressures will stay at a minimum because your airway is open. Turning on your back can collapse the airway and the AutoSet algorithm will increase the pressure. The AutoSet algorithm recognizes other conditions like sinus colds or allergies, which restrict nasal airflow. The AutoSet Advantage will increase treatment pressure accordingly, for whatever flow limitation may occur.

 

AutoSet with Easy-Breathe Technology

The S9 AutoSet uses Easy-Breathe Technology along with expiratory pressure relief (EPR) to make breathing through an APAP feel natural. At the onset of a flow limitation, the AutoSet algorithm responds with an increase of therapy pressure based on the degree of airflow restriction. Easy-Breathe technology aids in smoothing the pressure waveform during pressure increase. The process imitates normal respiration and ultimately makes breathing more comfortable than traditional CPAP machines. Easy-Breathe allows the user to receive the lowest pressure necessary to keep the airway open.

As an added benefit, Easy-Breathe allows the S9 Series to operate at 24dBA when set to 10cm of pressure from a distance of one meter. ResMed also managed to reduce the overall conducted noise that typically travels from the machine, through the tubing, and at the mask.

 

Expiratory Pressure Relief (EPR)

EPR decreases the pressure at the beginning of each breath and keeps the pressure low throughout the exhalation. The pressure is reduced by an exact pressure drop of one, two or three centimeters of water pressure. EPR gradually changes therapy pressures so there is little ventilatory effect. EPR also has an Event Detection Circuit. When a sleep disordered breathing event is expected or has occurred, EPR stops until the event concludes and normal breathing resumes.

 

SmartStart / SmartStop

SmartStart / SmartStop enables your device to start automatically by breathing into the mask. This feature automatically starts and stops your CPAP machine when you put on or take off your mask.

 

On-Display Advanced Data

There are two menus that provide users with information about compliance, therapy and machine settings: Standard Menu and Clinical Menu. Both can be reached by using the "Info" button on your machine, but the Advanced Info Menu will only appear if the machine is in its Clinical Mode.

 

Standard Menu

 Usage

 Mask Fit

 AHI

 Period

 Days Greater than 4 Hrs

 Average Use

 Total Used Hours

 

The Advanced Menu displays all the above plus:

 Days Used

 Pressure

 Leak Rate

Specification

S9 Technical Specification:

H5i Technical Specification:  
Operating pressure range: 4-20 см H2O
 
Maximum heater plate temperature: 65 C°
 
DImensions: 153 mm X 140 mm X 86 mm
 
Temperature cut-out: 74 C°
 
Weight: 0.81 кг
 
Dimensions: 153 mm X 145 mm X 86 mm
 
Housing Construction: Flame retardant engineering thermoplastic
 
Weight: 0.77 kg
 
Supplement oxygen: Recommended maximum oxygen flow 4 L/M
 
Water capacity to maximum fill line: 380 ml
 
Standard air filter: Polyester fiber
 
Housing Construction: Flame retardant engineering thermoplastic
 
Air outlet: 22 mm conical air outlet complies with ISO5356-1
 
Cleanable water tub injection molded plastic, stainless steel and silicone seal
 
General Specifications:
 
Air tubing specifications:
 
Power supply unit: 90W

Input range: 100-240V , 50-60 Hz, 110V 
 
ClimateLine air tubing: Flexible plastic and electrical components

Length: 1.89 m, 15 mm inner diameter
 
Typical power consumtion: 70W 

Maximum power consumption: 110W
 
SlimLine tubing: Flexible plastic and electrical components

Length: 1.89 m, 15 mm inner diameter
 

Operating temperature: +5 до +35 C°

Operating humidity: 5-95% 

Standard air tubing: Flexible plastic

Length: 2.0 м, 19 mm inner diameter
Operating altitude: Sea level to 2590 m 
 
Electromagnetic compatibility:
 
Sound pressure level: 24 dBA measured according to ISO 17510-1:2002  Product complies with all applicable electromagnetic compatibility requirements
 
  Aircraft use:
 
  Consult the medical services department of your carrier if need to use your S9 on board
 
  S9 devices comply with US FCC Part 15, Class B requirements
   

Video

Reviews

Write Your Own Review

You're reviewing: Auto CPAP device ResMed S9 AutoSet